RPI's New Inline Test System with Thermal Chamber -
Chamber Section (Hot, Cold, & Reheat)

 
   
There are three different chamber sections, hot, cold, and plain. All three types of chamber sections are very similar in construction. The common features include our 'sticky' top conveyor belts, triple sealing brush system, removable side plexi-glass shields, and power buss bars. They all have 4 inch thick insulated walls, and two access plugs to the top plenum of the chamber. A multi-layer glass window on the access plugs is an option. The standard length of a chamber section is 8 feet.

In addition to the above mentioned common features, a hot chamber section contains a squirrel cage style blower wheel, driven by a 5 hp motor. It uses (6) 240 volt 1.0 KW strip heaters for a total heat output capacity of 6.0 KW. These heaters are mounted to framework mounted inside the plenum. The side of the hot chamber contains an access plug which can be removed, allowing removal of the whole heater assembly.

A cold section consists of three main parts; a chamber, evaporator, and refrigeration. The cold chamber has two openings on the side wall of the lower plenum. One opening for air to enter, and a second opening for air to exit. These two openings are connected by short sections of insulated ductwork to the evaporator. The evaporator is contained in an insulated box with a blower wheel. This box can have either one or two evaporators. If it has two evaparators, the box employs a motor driven stainless sliding door which blocks flow through the defrosting evaporator. This allows the system to run twice as long before having to be defrosted, by switching between the two. It also provides the ability to keep running if a problem with a evaporator is encountered. The blower is a 22 inch diameter class III backward inclined aluminum wheel. It is driven by a 10 horsepower motor. The compressor package uses a 40 horsepower screw compressor.

As the name implies, a plain chamber section just has the common features of the other two and nothing else. This type of section is used in conjunction with either a main hot section or a main cold section to add length to the chamber.


The Hot/Cold Chamber Sections receives pallets from the previous door section and sequences the pallets according to a pre-programmed PLC timing sequence to achieve the desired soak time in the chamber. Temperature setpoints of the chambers are done via the system's operator interface touchscreen. If a test head is used at the end of the chamber, pallets will stop at the test head location for testing before being transferred to following door section. Pallets are transferred in and out via SMEMA interface.


 

   
   

 
     

 

2914 Carlisle Avenue

Racine, WI 53404 USA

Telephone: 262-633-6500 Fax: 262-633-5647

Copyright © 2003 RPI Inc.
All rights reserved.

BurninFixturing.com / BurninChamber.com

Specifications in this CD subject to change without prior notification. Photographs and images represented in this site are for informational purposes only and may depict optional or additional equipment not offered as standard. Always refer to the appropriate operator's manual for safe and proper operation of RPI equipment.